GSA 1736 PARTIAL EQUIPMENT INVENTORY LIST
BUILDING, NUMBER, NAME AND ADDRESS CT0013 - WILLIAM R. COTTER FEDERAL BLDG. 135 HIGH ST. HARTFORD, CT
PM GUIDE
NUMBER EQUIPMENT
NUMBER LOCATION MANUFACTURER MODEL / MODEL NUMBER SIZE
A-4 1 WATER MAIN ROOM GAST 5CLA-22-M500X 3/4 HP
A-4 2 CHILLER ROOM KARGARD A99927 200 PSI
A-4 3 CHILLER ROOM KARGARD A99927 200 PSI
A-7 1 FIRST FLOOR IRS CEILING YORK L-1EU240 20 TON 6,800 CFM
A-7 2 SOUTH BASEMENT COAST GUARD
CEILING CARRIER 50AH060500
A-9 1 SOUTH BASEMENT COAST GUARD CARRIER
A-9 2 BASEMENT CAFETERIA CEILING CARRIER 50AH500252
A-11 1 BOILER ROOM MEZZANINE MCQUAY LSL 111CH 10,700 CFM
A-11 2 BASEMENT CAFETERIA CEILING MCQUAY LSL 111CH 5,720 CFM
A-11 3 BASEMENT NURSE'S AREA MCQUAY LSL 111CH 3,850 CFM
B-3, 4 1 BOILER ROOM KEWANEE
B-3, 4 2 BOILER ROOM KEWANEE
B-4 1 BOILER ROOM AJAX B4E
B-6 1 BOILER ROOM ROSEMOUNT
C-2 1 BOILER ROOM MEZZANINE
C-2 2 BASEMENT WINDOW OPENING
C-2 3 BOILER ROOM MEZZANINE
C-2 4 BASEMENT
C-2 5 BASEMENT
C-2 6 FOURTH FLOOR SOUTH PENTHOUSE MECHANICAL
C-2 7 FOURTH FLOOR NORTH PENTHOUSE MECHANICAL
C-2 8 BASEMENT COAST GUARD CEILING
C-2 9 BOILER ROOM
C-4 1 BOILER ROOM JOHNSON CONTROL METASYS
C-5 1-111 THROUGHOUT OFFICE AREA ENVIRO-TEC (ETI) BY JOHNSON CONTROLS SSD-II
C-5 112-114 THROUGHOUT OFFICE AREA ENVIRO-TEC (ETI) BY JOHNSON CONTROLS WF-11
C-6 1-24 ON AHU SUPPLY PIPING JOHNSON CONTROL 130 G GA-1
C-6 25-48 MOUNTED ON AHU'S JOHNSON CONTROL A70HA-1
C-6 49-72 MOUNTED ON AHU'S JOHNSON CONTROL EDA-8102-1102
C-6 73-96 MOUNTED ON AHU'S ACTROL PENN / P32AC-2 & P32AF-2 12-1240 Pa
C-6 97-210 THROUGHOUT OFFICE AREA CEILING JOHNSON CONTROL
C-6 211-358 ON RADIATOR LOOP PIPING JOHNSON CONTROL VA-8050-a
C-7 1-13 AT EACH AIR HANDLER LITTLE GIANT 554902
C-9 1 NORTH ROOF EVAPCO LSTA-4-181 100 TON
C-9 2 NORTH ROOF EVAPCO LSTA-4-181 100 TON
C-10 1 NORTH ROOF EVAPCO LSTA-4-181 100 TON
C-10 2 NORTH ROOF EVAPCO LSTA-4-181 100 TON
C-13 1 BOILER ROOM
C-24 1 FIRST FLOOR ROOF YORK H1CE090A25A 10 TON
C-24 2 FIRST FLOOR ROOF YORK H1CE090A25A 10 TON
C-24 3 GSA OFFICE WINDOW WELL MCQUAY 2 TON
D-1 1 SECURE PARKING AREAS OVERHEAD DOOR 13'-6" X 15'
D-1 2 SECURE PARKING AREAS OVERHEAD DOOR 12'-6" X 15'
D-1 3 SECURE PARKING AREAS OVERHEAD DOOR 10' X 10'
D-3 1-50 ROOF AREAS
D-4 1-2 NORTHEAST ENTRANCE STANLEY
D-5 1-4 SOUTHEAST SIDE ENTRANCE
D-5 5-8 SOUTH SIDE ENTRANCE
D-5 9-20 SOUTHWEST ENTRANCE
D-5 21 LOADING DOCK
D-5 22 LOADING DOCK
D-5 23-26 LOADING DOCK
D-5 27 SECURE PARKING AREAS
D-5 28-29 SECURE PARKING AREAS
D-5 30 SECURE PARKING AREAS
D-5 31-32 HOADLEY PLACE
D-5 33 FOOTGUARD / NORTH SIDE
D-5 34-35 FOOTGUARD / NORTH SIDE
D-6 1-19 EAST AND NORTH WINDOW WELLS
D-6 20-22 FRONT PATIO AREAS
D-10 1-2 CAFETERIA ATLAS
E-19 1-10 DAYCARE SOUTH BASEMENT CORRIDOR
E-24 1 INSIDE MAIN FIRE PUMP CONTROLLER FIRETROL FTA435
E-26 1 INSIDE SWITCHBOARD "A" GENERAL ELECTRIC AKR-7D-50 1,600A
E-26 2 INSIDE SWITCHBOARD "A" GENERAL ELECTRIC TJL4V2606 600A
E-26 3 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC AKR-7F-100 4,000A
E-26 4 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC AKR-7D-50 1,600A
E-26 5 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC AKR-7D-50 1,600A
E-26 6 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC TEL136090WL 90A
E-26 7 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC TEL136090WL 90A
E-26 8 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC TEL136090WL 90A
E-26 9 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC TEL136090WL 90A
E-26 10 INSIDE SWITCHBOARD "B" GENERAL ELECTRIC TEL136090WL 90A
P-4 6 BOILER ROOM BALDOR 1/3 HP
P-4 7 CHILLER ROOM BELL&GOSSETT 4BC 8 BF 480 GPM
P-4 8 CHILLER ROOM BELL&GOSSETT 4BC 8 BF 480 GPM
P-4 9 CHILLER ROOM TACO FM3013 11.25 B2JD2L0
P-4 10 CHILLER ROOM TACO FM3013 11.25 B2JD2L0
P-4 11 BOILER ROOM VIKING GG4195 10 GPM
1800 RPM
P-4 12 BOILER ROOM VIKING GG4195 10 GPM
1800 RPM
P-4 13 CHILLER ROOM ECLIPSE HB-4615 15,300CFM
R-2 1-510 ALL ROOF AREAS 51,000 SQ FT
R-5 1 CHILLER ROOM YORK YT A2 B2 B2-CGE 200 TON
R-5 2 CHILLER ROOM YORK YT A2 B2 B2-CGE 200 TON
R-8 1 CHILLER ROOM YORK 031-00954 115V 15A